This happened after a firmware update was requested. This field is for validation purposes and should be left unchanged. Need Help? × Follow along with the video below to see how to install our site as a web app on your home screen. Setting parameters and FW update remotely, which makes PV plant O&M easier. Maybe I should have been more demanding or disconnected it from the wifi. HMI:VC.3.5.D Das hat mich eigens an Zeit gekostet und viel nachdenken . be connected to this port. Yes, the risk of updating firmware is quite high if you dont know what you are doing. You can post now and register later. Can someone help me with an issue with my Deye 8kw inverter? If you have an account, sign in now to post with your account. Inverter stays in standby mode and does not charge batteries. Your request for help is less likely to be seen here and you are pulling this thread off-topic for other people who are looking for firmware versions. I am installing my first Deye inverter and from experience with SunSynk I need to update the invertor if used with Revov batteries. Solar Equipment Reviews and Technical Support. But for me, I wont wait to encounter the problem that a firmware update made to fix that "not yet encountered problem". People really should make sure they know what they are talking about before spreading nonsense like that. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier. The Deye Technician accidentally flashed the unit with 5kw firmware and then reflashed it with the 8kw firmware. so i contacted deye directly via email and asked for the bin files for the SUN-5K-SG03LP1-EU inverter. Emailed Deye support but still waiting for a response. The labelling of the RS485 monitoring port is sometimes not intuitive. Your previous content has been restored. Information Betreiber 11. Service So aktualisieren Sie Ihren DEYE Mikrowechselrichter - Schritt-für-Schritt-Anleitung auf 2. Deye SUN600G3 und Bosswerk MI600 Firmware Update … Man muss also zunächst eine neue Firmware auf seinen Deye oder Bosswerk Mikrowechselrichter aufspielen. Since the upgrade I have had a lot of issues. drew on paper, then reproduced using MS Paint), Solar Equipment Reviews and Technical Support. If your inverter is on SOLARMAN and you email support with your serial number and ask to be upgraded, they’ll upgrade you at some point, but your inverter will reboot and you’ll loose power for a few minutes if you’re using it as an UPS power source. Some people are "aint broke aint fix". The one thing where people get scared of firmware updates is that if you mess up the update process, e.g., by interrupting it or using the wrong firmware then you can render the device inoperable or "bricked". Protocol Version:V0.2.0.1 of the inverter. Their last mail was "We have replaced the firmware for you. Dont they have some checksum checking? If anyone gets hold of the actual firmware files for the same main version for each brand I'll see if I can unpack them and verify if the contents are identical and not just the version numbers. I think that is why they are afraid of releasing firmwares publicly, because they themselves can f*ck up. I got mine 3rd March, same version as yours. SUN-(1-4)K-G04P1-EU-AM1-String Manual-Ver2.-Deye-13A; SUN-(3.6-6)K-G-String Manual-Ver2.-Deye-12.5A; SUN-(7-10.5)K-G-String Manual-Ver2.-Deye-25A Changes: The SUN 600/800/1000G3 is optimized to accommodate today's high output PV modules effectively with up to 500W output and dual MPPT. Could you drop me a DM regarding that 15KHz noise you have man? For a better experience, please enable JavaScript in your browser before proceeding. I would recommend asking politely for a copy of the release notes. Latest Firmware 0000-C35C adds new Grid Settings. Firmware Update Process Based on a few forum entries and the answer from Deyes support the Inverters should auto-update to the latest version when being up and running for 30 minutes. 【Rich Equipment Types】 breaking the traditional limitation, it can comprehensively. Zero export application, VSG application. file size: 40 MB, Max. Deye sent new firmware which resolved the problem. The startup voltage of 250V, much lower than 600V of other products, which makes the inverter start up earlier to generate more power with longer working time. We're playing numbers and shooting aimless here without the changelog. Contribute to dasrecht/deye-firmware development by creating an account on GitHub. Please see the list below for the correct Extended System Version:V1.1.00.0F I also noticed that other than the HMI (Human Machine Interface??) Hey, he is not wrong, we dont get documentation, so we assume its just changes in versioning according to that distributor. Lucky you, Deye did not seem inclined to send me any files or guides. Its not that I cant its that Im a little scared to blindly update it seen to many people having issues with deye updates so was hoping somebody could confirm their version numbers to give me a little more confidence. China. Hersteller von Solar-Wechselrichtern. Use Energy Pal to have professionals install an offgrid system. I posted it here as the problems started after a firmware upgrade, so that people are aware of the issues with that firmware version and don't have the same issues as I have had and ignore/skip that version. Januar 2023 #1 So, nach einigen Stunden Recherche meine Zusammenfassung aus verschiedenen laaangen Threads: Im Web-Interface unter Upgrade / Upgrade firmware kann man eine Datei hochladen und upgraden. Hi can any one help please Deye did an firmware upgrade today i only saw now that my inverter is showing off grid but my grid is on . Please specify: 1) HMI (LCD) and Main (Control Board) Versions 2) Original firmware or upgraded 3) Date of upgrade 4) Inverter Model 5) Split Phase? Deye SUN-5K-SG03LP1-EU User Manual (46 pages) Hybrid Inverter. #1 Hi, I'd like to start a thread tracking which firmware versions Deye users are using. Im glad you started this thread although there is already for sunsynk which in my opinion is identical in main firmware, only HMI will vary, so I could track if there is an update. Hier meine Infos damit der Deye Wechselrichter auch per App oder in der cloud Daten liefert. * to 6.x so I can't tell you in what version the changes were introduced. DEYE 16Kw, Was delivered in April 2023 with. So sad to see these kind of topics due to lack of documentation from the manufacturer. #1 Moin Zusammen, das Thema wird ja bald interessant. Your previous content has been restored. I have just been updated to C362 from C35C. They suggested that you update the lcd first to avoid reboot, then finally the board (3382). × See, Note with the latest 16kW models/firmware the BMS port is used for SolarAssistant monitoring and battery CAN MAIN: Ver 0-3384-151 Need Help? HMI: Ver 0000-C362 Main: Ver -9022-1725. I insisted, so it fixed the 9.9a clipping and he is now using it to promote sales. Open station supports one-click installation and registration Problem support one-click dispatch and navigation Grid Interactive and Inspection Approved 48V System, Solar Friendly Heat Pump Air Conditioners. Aren't Deye publishing official firmware releases with official release notes on an official release channel? Δdocument.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); No.26 South Yongjiang Road, Beilun, Ningbo, Zhejiang, 315806 P.R. As it turns out it seems that it was not so much the settings in the firmware but the firmware code that uses those settings. You must log in or register to reply here. Der SUN 600/800/1000G3 ist ein netzgebundener Mikro-Wechselrichter der neuen Generation mit intelligenten Netzwerk- und Überwachungssystemen, um maximale Effizienz zu gewährleisten. Februar 2023 Update vom 03.04.2023 Nutzer melden sporadische Netzwerkausfälle beim Deye Wechselrichter Mehrere Kunden haben in den letzten Tagen gemeldet, dass der Deye Wechelrichter morgens nicht mehr "angelaufen" ist. This was on 23 Feb 2023 and the wireless logger dongle has been working well to date. Protocol Version:V0.2.0.1 × However, as someone who has compiled release notes, not everything that gets changed makes it into the release notes. That was when the 9.9a clipping issue for 5kW. USB ports. Sadly, the 15kHz noise is still there. Deye Firmware Tracker Thread themizz May 4, 2022 Prev 1 2 C cods4 Solar Enthusiast Joined Sep 21, 2021 Messages 174 Oct 6, 2022 #21 The middle section are the parameters that the grid needs to fall into after the inverter will reconnect to the grid. SolarAssistant device as long as the inverters are configured as a parallel installation. You can post now and register later. Also developers seem to not enjoy writing release notes. Pasted as rich text. can be plugged into the RS485 port located on the inside the inverter. Select the USB port where your inverter is connected. Better to ask them first for confirmation. Factory cover over 15,000m² and complete production and testing equipment, Deye has become a . Display as a link instead, × MAIN_1:V6.0.2.2 Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs. If you have multiple inverters, you need to multi-select multiple . Model: Deye 8 kw single phase. Copyright © 2023 Ningbo Deye Technology Co., Ltd. | Designed by, Higher yields / Safe & Reliable / Smart / User-friendly. × Can you downgrade firmware? It does not use or integrate with the WiFi dongle Why aren't these files just available from their website? 2 MPP tracker, Max. port. Deye smart cloud big data will help you to build your own photovoltaic power station in the shortest time. See how I fixed them. Anmelden Datenschutz-Bestimmungen Datenschutz-Bestimmungen The inverter does not behave like it should. they then emailed me a 1 line response and 2 bin files. 22/03 Update: Firmware was updated on 20th March, remotely by Deye, to 3382-1515. MAIN_2:V0.7.1.7 You nailed everything what I wanted to say sir! Prior to that I had managed to resurrect multiple pieces of hardware at work that were considered broken by following the recovery process to update the firmware on them. I have upgraded to the latest firmware that Deye support sent me for my Deye 8KW inverter. Over the years I have worked with a lot equipment that had firmware in it. I would appreciate it if you could share the files. I'll post it here if they eventually send it. Higher yields / Safe & Reliable / Smart / User-friendly Does anyone here have the firmware files even it is outdated. Pasted as rich text. China. Clear editor. HMI:VC.3.5.D I am looking to understand how I check the firmware version to ensure they have the latest and if not how to obtain the latest and upgrade. When connecting multiple inverters, SolarAssistant will show a combined view while still making individual inverter SUN-SG03LP1-EU 5KW updated beginning of September. Although I see in a separate thread that my troubles may be related to faulty cables. Why are you asking technical support questions about battery charging problems in a thread about firmware versions? Die Platinen 600W 800W 1000W sind ja alle gleich. Note: This feature currently requires accessing the site using the built-in Safari browser. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier. On the SolarAssistant configuration page, select "Deye, SunSynk, Sol-Ark" as your inverter model. https://workupload.com/file/M4WMQxJSjQd. Same issue happend to me they flashed my inverter (3k 24v) with wrong inverter(3.6k 48v) and reflashed with the right one, but the inverter still recognise himself as 3.6k 48v, How did you solve your problem please help. Product Overview. Interface now says Off Grid instead of a red x when there is load shedding. PV inverter manufacturer and Solar On-grid, Grid-tie inverter suppliers in China. It may not display this or other websites correctly. Protocol Version:V0.2.0.1 2. This thread is for tracking the latest Deye Inverter firmware. has anybody done a manual upgrade before and know what deye's naming convention is? Der SUN 600/800/1000G3 ist optimiert, um die heutigen Hochleistungs-PV-Module mit bis zu 500 W Leistung und dualem MPPT effektiv aufzunehmen. These inverters have two ports that can be used for monitoring. What inverter capacity, and whats the latest version? This is one possible reason why a manufacturers may not want to make the firmware files available for download. Follow along with the video below to see how to install our site as a web app on your home screen. That assumes of course that the firmware is distributed in separate files or the separate files are bundled together in a way that can be unpacked. Die Sicherheitslücke in dem . I'm a guy that if there is a firmware update, then it literally means there is an update to atleast improvement if not fix. This is an RS485 cable with a specific RJ45 Interface now says Off Grid instead of a red x when there is load shedding. To "unbrick" it I had to solder some pins onto the PCB to be able to connect a serial cable and resurrect it by installing the correct firmware on it. Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs.Setting parameters and FW update remotely, which makes PV plant O&M easier. Your link has been automatically embedded. communication at the same time. How do I go about it? pinout that can be purchased in our online store. Hersteller Deye reagierte am 8. Setting parameters and FW update remotely, which makes PV plant O&M easier. Logger / Wireless Dongle: You can connect multiple inverters to a single Step 2 - Configure SolarAssistant to connect to a Deye/SunSynk/Sol-Ark. Version Information It's. I have "bricked" exactly one personal device when I forced the firmware for a different piece of hardware on it. Anyone know if the Deye and OHM (also made by Deye and appear identical) inverters share the same firmware? On 2023/04/09 at 12:11 AM, Oberfail said: On 2023/02/20 at 4:02 PM, SmittySmit said. Max 4 MPP tracker, Max. I kinda want to hoard these files for future reference. efficiency up to 98.7%, 176Vac~242Vac(this may vary with grid standards), CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11, IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2. Seems like Solark and Sunsynk also don't publish official release notes. Don't do that guy, start a new thread! Btw in my earlier reply I did not mean that your batteries were faulty but that the inverter may have had the wrong settings for the battery stored in its firmware and thus did not want to charge them. MAIN_2:V0.7.1.7 not yet. some versions use the same hardware and KW are defined by firmware and they don't want us to buy a 5K and upgrade for higher without paying extra. Each inverter will require it's own USB cable. Inverter was installed 2 days ago and now it is not working properly. Requested an update as I was having a few generator issues. you might already have. Setting parameters and FW update remotely, which makes PV plant O&M easier. It looks like you have a newer Human Machine Interface (C362) than what I have (HMI:VC.3.5.D) but they seem to have downgraded your main firmware slightly from 6.0.2.2 to 6.0.2.0. This series inverter is specially designed for 127/220Vac three-phase system, especially suits for South American areas. Anstatt alle 600W WR wegzuwerfen und gegen 800W zu tauschen sollten wir hier mal alles zusammentragen was wir tun können um das selber bzw. MAIN:3382-1515, Hi, I just installed a new Deye inverter 27th of Feb 2023. The manufacturers who release new versions are not releasing them for fun. USB ports. SolarAssistant connects to these inverters via a physical cable. Is it essentially required to update them, and how is the procedures to do that through Solarman? built USB RS485 cable Higher yields / Safe & Reliable / Smart / User-friendly So the problem were never the batteries, but firmware as everything worked perfectly before and after the faulty firmware. One would think they would, but no. The BMS port is used for SolarAssistant Fair enough, I could tell you what I noticed changed in the interface but the firmware was upgrade from version 3. Company founded in 2007 with registered capital 205 million RMB (Over 30 million USD), is one of the China's high-tech enterprises and a subsidiary of Deye Group. Main differences from a menu side seem to be around the grid power settings available. The startup voltage of 250V, much lower than 600V of other products, which makes the inverter start up earlier to generate more power with longer working time. Thanks. A purpose supports the Deye inverter, it will most likely not work. HMI: Ver 0000-C361 Februar mit einer Pressemitteilung: Künftig soll es die reparierte Firmwareversion (1.53 . You cannot paste images directly. Max 4 MPP tracker, Max. Brand: Deye | Category: Inverter | Size: 5.85 MB Table of Contents. Accepted file types: jpg, gif, png, pdf, Max. They explained to me before that the mcu bin is for the lcd, and the other one is for the main board. The single-phase inverter is one of the best options for residential applications thanks to its smaller size and local LCD display and buttons. SUN 5/6/8/10/12K-SG is brand new three phase hybrid inverter with low battery voltage of 48V, ensuring the system safe and reliable. (for Caribbean use, for example) 6) Feature enhancements/bugs or other notes. Urheberrechte ©Ningbo Deye Inverter Technology Co., Ltd. Alle Rechte vorbehalten. Paste as plain text instead, × And the overvoltage 10min average is fairly self explanatory. Copyright © 2023 Ningbo Deye Technology Co., Ltd. | Designed by, Higher yields / Safe & Reliable / Smart / User-friendly. On the SolarAssistant configuration page, select "Deye, SunSynk, Sol-Ark" as your inverter model. Equipped with large LCD and buttons, easy to operate and maintenance. Power Forum. I.e it has tripped for some reason (low frequency for example). Table of Contents. I noticed at least two changes in the interface between the two versions. file size: 40 MB, Max. Check your battery settings in the inverter, if the voltages are wrong then that could explain why your inverter has been complaining about DC Low Voltage for more than a year. Updated to what I assume is the latest. 4. Module Version No:LSW3_15_FFFF_1.0.86D If you have an account, sign in now to post with your account. I.e it has tripped for some reason (low frequency for example). Posted June 1, 2022 This thread is for tracking the latest Deye Inverter firmware. For a better experience, please enable JavaScript in your browser before proceeding. Some updates require an additional LCD update, so if you run a version older than 3382, i do not suggest you to update. Description Higher yields / Safe / Smart / User-friendly The SUN 600/800/1000G3 is a new generation grid-tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. I've just received update to the above mentioned firmware after requesting from Deye. can be plugged into WiFi RS232 port located on the bottom Product Features . Deye service department stopped responding after they flashed my inverter with the wrong firmware. Lastest firmware deye 8KUS is 5221 for the mcu2, Możesz zmienić oprogramowanie przez WiFi logger, wprowadź jego IP w przeglądarce, po zalogowaniu zobaczysz tam opcje, oprogramowanie wyśle Ci usługę deye sun pocztą e-mail. . Let's keep this thread clean related to firmware versions. Is a special cable required? Click connect: Product Size. The single-phase inverter is one of the best options for residential applications thanks to its smaller size and local LCD display and buttons. Each inverter will require it's own USB cable. Don't tell anyone but if the underlying firmware is the same then it may be possible to flash a Deye with Sunsynk firmware and vice versa. This series inverter is specially designed for 127/220Vac three-phase system, especially suits for South American areas. durch Deye machen zu lassen. On the positive side I did send them one email and the next day they confirmed the serial number and then performed the firmware update so they are at least quick about it. monitoring and battery CAN communication at the same time. Surprisingly after 5982 they went down to 5213, I've also been updated to C35C after I had some issues with parallel communications between inverters on C3FC. efficiency up to 97.5%. this was Friday morning 07:01, Radio silence from then even after more than 14 mails to countless contacts. That certainly saved buying new ones. On 2023/02/23 at 11:10 AM, krugerjq said: On 2022/06/01 at 9:06 PM, SmittySmit said. Power Forum. Nun hat Deye jedoch angekündigt, das Firmware-Update automatisch auf allen Wechselrichtern einzuspielen, die mindestens 30 Minuten mit dem Internet verbunden sind. The BMS port is used for SolarAssistant monitoring and battery CAN communication at the same time. Equipped with large LCD and buttons, easy to operate and maintenance. What is the procedure to upgrade the firmware and what do you need? Did you manage to do the firmware update? You cannot paste images directly. 1 Jun 20, 2022 #1 I have two Deye 8K Hybrid Inverters installed and being monitored via SolarAssistant. efficiency up to 97.5%. Only post the firmware details here. See, Note with the latest 3 phase models/firmware the BMS port is used for SolarAssistant monitoring and battery CAN Select the USB port where your inverter is connected. The version numbers exist to keep track of the differences in the compiled software code that runs on embedded devices, i.e., firmware. P.S. When I asked them for an upgrade I mentioned that I was having trouble getting the inverter to talk to the batteries in Lithium mode so I have it setup to use voltages. HMI:VC.3.5.D Smart Monitoring Platform Upload or insert images from URL. I believe the latest is 3382 c35d for deye 5k. 127/220Vac and 60Hz, three phase system. Setting parameters and FW update remotely, which makes PV plant O&M easier. Doch das ist nicht ohne Weiteres möglich, da es trotz bekannter Sicherheitslücke und trotz aktueller Firmware Version keinen neuen Firmware Download von Deye oder Bosswerk gibt. The middle section are the parameters that the grid needs to fall into after the inverter will reconnect to the grid. When I set the Grid to charge the batteries, it still does not do it. Clear editor. I can also reveal that no problems have been observed with the new version. When using this option, you will not be able to use the standard Deye/SunSynk/Sol-Ark dongle as the dongle can only Note the latest 5kW models doesn't have a separate CAN port. Display as a link instead, × Ah, fair enough. Also, with built-in zero-export function (external CT is needed), it offers true ease and comfort for PV system operators and installers. You use the logger's webpage. 48V low voltage battery . Thanks to the smart monitoring platform, Deye full series inverter products support remotely shutdown immediately when accident occurs. Proceed at your own risk though. 4.15K subscribers Subscribe 9.6K views 1 year ago CHRIST EMBASSY CAMP GROUND Our inverters stopped working when the factory pushed through firmware on one of them. The SUN 600/800/1000G3 is a new generation grid-tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency.