Huawei Technologies Co. Ltd. Log in to the FusionSolar app, choose Device Commissioning > Settings > Communication configuration > Router connection settings, and set router parameters. Huawei Enterprise Support Community. No relevant resource is found in the selected language. Choose the types of newsletters you want to receive! User Guide. Password: "00000a" is not accepted because it is too short. (0) #422 05 Jan 2022 09:34 ak12345 - after updating the firmware, I had to do a quick configuration again and the most important step was to find the optimizers again, without that, my production did not start. Stay connected! Thanks for using Huawei Enterprise Support Community! To obtain better user experience, upgrade the browser to the latest version. solutions. Your password might be stolen or cracked if it is left unchanged for extended periods. Otherwise, the communication between them would be affected. In these cases, the Company shall not be liable for any loss caused to the plant. I agree to receive recommendations that I might be interested in based on my daily behaviors such as post reply, like, and browse. ak12345 - after updating the firmware, I had to do a quick configuration again and the most important step was to find the optimizers again, without that, my production did not start. Wait until all the LED indicators on the SUN2000 panel turn off. If you do not set basic parameters for the inverter on the quick settings screen, the screen is still displayed when you log in to the app next time. After logging in: Plants -> Device -> Upgrade Management. The USB data cable is connected from the USB port at the bottom of the SUN2000 to the port on the mobile phone. Log in to the FusionSolar app, choose Device Commissioning > Settings > Communication configuration > Inverter WLAN settings, and reset the WLAN password. If a password is lost, devices cannot be accessed. Page 2 The screw is used to secure the DC switch to prevent accidental startup. When you log in to the system for the first time, set the login password. Ensure that the indicator is blinking green slowly. Users on your blacklist cannot comment on your post,cannot mention you, cannot send you private messages. Are you sure to block this user? To ensure account security, change the password periodically and keep the new password in mind. Wait until the indicator blinks green at long intervals. The screw is delivered with the solar inverter. The SUN2000 app version must be 3.2.00.013 (Android) or later, and the FusionSolar app version must be 5.7.008 (Android) or later. solutions. User Guide. Office. Obtain the initial WLAN hotspot name (SSID) and initial password (PSW) from the label on the side of the SUN2000 and connect to the App. I am a beginner in HA and here I feel that it is even higher, I am a beginner in HA and here I feel that it is even higher. Use the initial password upon first power-on and change it immediately after login. Stories, Digital Transformation: The actual screens may vary. Someone can show or write what are the reactive power settings in the inverter? This scenario is for Sun2000 M0 inverter scenario.If you met this issue with the password of installer when you commissiong the inverter you will need . For details about the permissions of an installer user, see those of advanced and special users. Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Turn off the AC switch and set the DC switch to OFF. A password left unchanged for a long period of time may be stolen or cracked. Language |. If the device has been connected to the SmartLogger, the quick settings screen is not automatically displayed when the device is connected to the app. The following parameter settings use advanced and special users as examples. The login user is an Installer user. I agree to receive recommendations that I might be interested in based on my daily behaviors such as post reply, like, and browse. Leave your details and we'll be in touch. Reset the password within 10 minutes. You can Sign Up for free! (If no operation is performed within 10 minutes, all inverter parameters remain unchanged.). 2018-10-19 eu_inverter_support@huawei.com Page1, Total18 . The SUN2000 app version must be 6.22.10.117 (Android) or later, and the FusionSolar app version must be 6.22.10.117 (Android) or later. (If no operation is performed within 10 minutes, all inverter parameters remain unchanged.) SUN2000L COMMISSIONING GUIDE EU . When the WLAN connection is used, the initial name of the WLAN hotspot is, When the Bluetooth connection is used, the connected Bluetooth device is named after, (Scenario in which the SUN2000 is connected to the FusionSolar hosting cloud) Run the FusionSolar app and access the. (Optional) Installing the Power Cable of the Tracking System, Connecting Cables to Amphenol Helios H4 Connectors, Connecting Cables to Staubli MC4 Connectors, Connecting the RS485 Communications Cables. I agree to receive email notifications from the Huawei Enterprise Support Community and I understand that I can unsubscribe at any time. Tauron's SIDE suggested that the compensation should be active in order to minimize the number of inverter shutdowns in high sunlight, but I suspect that it is just help desk gibberish so that there is something to paste and close the application. Obtain the initial WLAN hotspot name (SSID) and initial password (PSW) from the label on the side of the SUN2000 and connect to the App. Sun2000 5 KTL-L1 wifi/installer password is not working - Huawei Enterprise Support Community. An error occurred when loading the video. Reset the password within 10 minutes. The login password is the same as that for the SUN2000 connected to the app and is used only when the SUN2000 connects to the app. Hey dear, to those who have recently bought the dtsu666-h meter, can I ask you for directions to stores or wholesalers, where you managed to buy it relatively painlessly and within a reasonable time? Reset the password within 10 minutes. At this point, it seems easiest to get the script to work. You can also turn the inverter off and on. Choose the types of newsletters you want to receive! Community Forums Groups Blog & Collections Rewards FAQ Top Members Subscribe. Instantly find the answers to all your questions about Huawei products and When you log in to the system for the first time, set the login password. |. the dongle was not locally visible when I connected through the app directly to the inverter. Huawei Enterprise Support Community. The SUN2000 app version must be 6.22.10.117 (Android) or later, and the FusionSolar app version must be 6.22.10.117 (Android) or later. Products, Solutions and Services for Enterprise, Smartphones, PC & Tablets, Wearables and More. How to make a template to count the production from the last month? Quick Settings Your browser version is too early. This means that you have deleted the password needed for connection, go to the inverter and turn on the WiFi scan on the phone, when your SUN2000-2050084xxxx inverter pops up, click on it and enter the password provided on the side of the inverter. Call the installer for the password, or you can reset the inverter and set a new password yourself Sesjusz Level 10 » | Helpful post? Your browser version is too early. If the USB data cable is successfully connected, the message. Sun2000 5 KTL-L1 wifi/ins. Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Thanks Akir! Language |. The WLAN or Bluetooth function is enabled. Hotline, Branch Everything is clear, I have no authorization, so I could not find it. 2. Turn on the AC switch and set the DC switch to ON. • b: DC input terminals PV1 and PV2 are . Products, Solutions and Services for Enterprise, Smartphones, PC & Tablets, Wearables and More. (Scenario in which the SUN2000 is connected to other management systems) Run the SUN2000 app and access the operation screen. Contact Us: e_online@huawei.com Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Summary of Contents for Huawei SUN2000 L1 Series. The screenshots are for reference only. You can change lines. Does ModBus work for you in the inverter AP (ktl-m1) in the SPC140 version (the one on 192.168.200.x: 502)? Wait until all LED indicators on the SUN2000 panel are off. The actual screens may vary. Turn on the AC switch and set the DC switch to ON. Not changing the initial password may cause password disclosure. Thanks for using Huawei Enterprise Support Community! We will help you learn how we collect, use, store and share your personal information and the rights you have in accordance with. Enterprise products, solutions & services, Products, Solutions and Services for Carrier, Phones, laptops, tablets, wearables & other devices, Network Management, Control, and Analysis Software, Data Center Storage Consolidation Tool Suite, Huawei CloudLink Video Conferencing Platform, One-stop Platform for Marketing Development, City of Contact Us: e_online@huawei.com Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Products, Solutions and Services for Enterprise, Smartphones, PC & Tablets, Wearables and More. No account yet? Community Forums Groups Blog & Collections Rewards FAQ Top Members Subscribe. Keep the mobile phone within 5 m from the SUN2000. Version Created by Date Remarks . If a password is lost, devices cannot be accessed. Perform the following operations within 4 minutes: Reset the password within 10 minutes. Wait until the indicator blinks green at long intervals. Instantly find the answers to all your questions about Huawei products and I wanted to make a rule at home that when I have a production greater than X, it starts my socket with a certain power-hungry device plus a few more actions, so I wanted an HA, in which I would also operate a number of sensors. Intelligence, 100 Digital Transformation (If no operation is performed within 10 minutes, all inverter parameters remain unchanged.) Enterprise products, solutions & services, Products, Solutions and Services for Carrier, Phones, laptops, tablets, wearables & other devices, Network Management, Control, and Analysis Software, Data Center Storage Consolidation Tool Suite, Huawei CloudLink Video Conferencing Platform, One-stop Platform for Marketing Development, City of Remember Me | Forgot Password | New Activation, Call the installer for the password, or you can reset the inverter and set a new password yourself. Stay connected! Looking to make a purchase? Not sure if you have a user or farm owner account? It works on the cable and on WiFi from the dongle. When he gets up, Dongle issues AP for a few minutes. The DC or AC side of the SUN2000 has been energized. I agree to receive email notifications from the Huawei Enterprise Support Community and I understand that I can unsubscribe at any time. Unfortunately, I have no idea how to run the program. Choose the types of newsletters you want to receive! In these cases, the user is liable for any loss caused to the PV plant. Login. An error occurred when loading the video. a year from launch, you can use something like this: I will only add my three cents, because I also have an inverter connected with HA, that all these charts look cool on the screens and I was also fascinated with them before they connected the panels to me, but in the end I'm from people who look there several times a day (I have PV 2 weeks maybe it will pass. Because I noticed that it is no longer available and I do not have permission to download the Release Notes ... Huawei SUN2000 Inverter: WIFI Dongle Connection, Firmware Update & FusionSolar, https://community.home-assistant.io/t/integration-solar-inverter-huawei-2000l/132350, https://gitlab.com/Emilv2/huawei-solar/-/blob/master/src/huawei_solar/huawei_solar.py#L1010, https://community.home-assistant.io/t/integration-solar-inverter-huawei-2000l/132350/225, https://region04eu5.fusionsolar.huawei.com/, https://region04eu5.fusionsolar.huawei.com/pv...x.html#/settings/devupgrade/device-versionmgr. Set router and management system parameters to implement remote management. Turn on the AC switch, set the DC switch to ON, and wait for about 90s. Indicators. So a downgrade wouldn't help either. The actual login screen may vary. Single-phase grid-tied pv string inverter (151 pages), Manual will be automatically added to "My Manuals", Inverter Huawei SUN2000-2KTL-L1 User Manual, Audio & Video Accessories Huawei SUN2000-2KTL-L1 User Manual, Wireless Access Point Huawei SUN2000-2KTL-L1 User Manual, Inverter Huawei SUN2000-6KTL-L1 Quick Manual, Inverter Huawei SUN2000-4.6KTL-L1 Quick Manual, Inverter Huawei SUN2000-5KTL-L1 Installation Manual, Inverter Huawei SUN2000L-5KTL Quick Manual, Inverter Huawei SUN2000L-2KTL Quick Manual, Inverter Huawei SUN2000L Series User Manual, Inverter Huawei SUN2000L-3KTL Quick Manual, Page 8: Installing The Ac Output Power Cable, Page 20: Customer Service Contact Information. I wanted to make a rule at home that if I have a production greater than X, it starts my socket with a certain power-hungry device plus a few more actions. Man, it's linden. Community Forums Smart PV. You can change lines. Huawei solar WIFI password settings Solar4Ever 423 subscribers Subscribe 98 Share 17K views 1 year ago MORLEY How to enter or change the WIFI settings for your Huawei solar inverter using. Turn off the AC switch and set the DC switch at the bottom of the SUN2000 to OFF. During the login, if five consecutive invalid password entries are made (the interval between two consecutive entries is less than 2 minutes), the account will be locked for 10 minutes. Ensure that the SUN2000 connects to the AC and DC power supplies at the same time. Apparently, you can disconnect and connect the dongle, then it works in AP mode for some time. The actual screens may vary. Go to the entities and expand the attributes you have all the information, Below what it looks like after opening the entity. Stories, Digital Transformation: I've been working on it for a long time, something I probably don't know, or maybe something wrongly entered in the scripts, Thank you Ggitpusher, it looks great for you. Run the app and select a connection mode. A calendar month, if you want to measure according to specific dates, e.g. You will be locked out for 10 minutes after five consecutive failed password attempts (the interval between two consecutive entries is less than 2 minutes). The initial password for Common User, Advanced User, and Special User is 000001. If the installer password was changed and you've forgotten it, restart the inverter 2 times within 3 minutes (disconnect and connect the AC and DC 2 times). No relevant resource is found in the selected language. I'm pretty sure then it needs to be physically turned off and on. Select a login user and enter the login password to access the quick settings screen or the main menu screen. I agree to receive recommendations that I might be interested in based on my daily behaviors such as post reply, like, and browse. Turn off the AC switch and set the DC switch to OFF. Log in to the FusionSolar app, choose Device Commissioning > Settings > Communication configuration > Management System Configuration, and set management system parameters. Community Forums Smart PV. Obtain the initial WLAN hotspot name (SSID) and initial password (PSW) from the label on the side of the SUN2000 and connect to the app. Contact Us: e_online@huawei.com Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Leave your details and we'll be in touch. Some functions of the website may be unavailable. I am not a fan of charts, I saw on some home assistant forum our compatriot wrote down the charts beautifully. If you log in to the app after the device connects to the app for the first time or factory defaults are restored, the quick settings screen will be displayed. Office. SUN2000 3KTL Password los. To obtain better user experience, upgrade the browser to the latest version. Stay connected! Login. Connection over a WLAN module or a Bluetooth module: The WLAN module or Bluetooth module is connected to the. I did it through the utility meter does it count the calendar month or 30 days from commissioning? On the login screen, set a new login password and log in to the app. To set SUN2000 basic parameters on the quick settings screen, switch to. I agree to receive email notifications from the Huawei Enterprise Support Community and I understand that I can unsubscribe at any time. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Perhaps it is better to stay on the new firmware, but do this initial configuration by logging directly to the inverter's wifi and there on the installer's account. Page 1 SUN2000- (2KTL-5KTL)-L1 Quick Guide Issue: 03 Part Number: 31500DQD Date: 2020-04-14 Huawei Technologies Co., Ltd. Wait until all LED indicators on the SUN2000 panel are off. The screenshots are for reference only. Hotline, Branch SUN2000 App to access the Inverter SUN2000 model 33-A, 36, 42,50,55,60,100,105 KTL and Smartlogger2000 The SUN2000 APP (APP for short) is a mobile application that communicates with the Huawei inverter or Smartlogger2000 through Bluetooth or a USB data cable.